• 1 - Banner

PDU

  • 36 PORTS P14&8 PORTS C19 BASIC RACK PDU

    36 PORTS P14&8 PORTS C19 BASIC RACK PDU

    Zofunikira za PDU:

    1. Kuyika kwamagetsi: magawo atatu 346 ~ 480V

    2. Zolowetsa Panopa: 2*(3*125A)

    3. Kutulutsa mphamvu: gawo limodzi 200 ~ 277V

    4. Kutuluka: 36 madoko a 4-pin PA45 (P14) Sockets 8 madoko a C19 Sockets

    5. Madoko awiri Integrated 125A main circuit breaker (UTS150HT FTU 125A 3P UL)

    6. Doko lililonse lili ndi 1P 277V 20A UL489 Hydraulic Magnetic circuit breake

  • 40 PORTS C19 BASIC RACK PDU

    40 PORTS C19 BASIC RACK PDU

    Zofunikira za PDU:

    1. Kuyika kwamagetsi: magawo atatu 346 ~ 480V

    2. Zowonjezera Pano: 3 * 250A

    3. Kutulutsa mphamvu: gawo limodzi 200 ~ 277V

    4. Kutuluka: Madoko a 40 a C19 Sockets okonzedwa m'magawo atatu

    5. Doko lirilonse liri ndi 1P 20A wozungulira dera

  • 18 PORTS C19&2 PORTS C13 BASIC PDU

    18 PORTS C19&2 PORTS C13 BASIC PDU

    Zofunikira za PDU:

    1. Kuyika kwa Voltage: magawo atatu 346 ~ 415V

    2. Zolowetsa Panopa: 2 seti ya 3 * 60A, imodzi mbali iliyonse ya PDU

    3. Kutulutsa mphamvu: gawo limodzi 200 ~ 240V

    4. Chotulukira: 18 zodzitsekera zokha C19 Sockets (20A Max) 2 zodzikhoma C13 Sockets (15A Max)

    5. 6 ma PC 1P 60A UL489 ophwanya, iliyonse imateteza zitsulo zitatu

    6. Awiri doko C13 kwa masiwichi maukonde

    7. Kupaka ufa : Pantone Black

  • 18 PORTS C19 PDU

    18 PORTS C19 PDU

    Zofunikira za PDU:

    1. Kulowetsa mphamvu: 3-gawo 346-415VAC

    2. Zolowetsa panopa: 3 x125A

    3. Kutulutsa mphamvu: gawo limodzi 200 ~ 240 VAC

    4. Kutuluka: Madoko 18 azitsulo za C19 zokhala ndi zotsekera zokonzedwa m'magawo atatu

    5. 3P 125A UL489 Hydraulic Magnetic main circuit breaker

    6. Doko lililonse lili ndi 1P 20A UL489 Hydraulic Magnetic circuit breaker

  • 18 PORTS C13 PDU

    18 PORTS C13 PDU

    Kufotokozera kwa PDU:

    1. Kuyika kwa Voltage: magawo atatu 346 ~ 415V

    2. Zowonjezera Pano: 3 * 100A

    3. Kutulutsa mphamvu: gawo limodzi 200 ~ 240V

    4. Kutuluka: Madoko a 18 a C13 Sockets adakonzedwa m'magawo atatu

    5. 9 × 32A 1P ophwanya, aliyense Circuit Breaker amawongolera zitsulo ziwiri

    6. Doko limodzi la C13 la maukonde, ndi 1P / 2A yopuma

  • 6 PORTS C19 SMART PDU

    6 PORTS C19 SMART PDU

    Zithunzi za PDU

    1. Mphamvu yamagetsi: magawo atatu 346 ~ 400V

    2. Zolowetsa Panopa: 3 * 32A

    3. Kutulutsa mphamvu: gawo limodzi 200 ~ 230V

    4. Chotuluka: 6 doko C19 sockets, yokonzedwa m'magawo atatu

    5. Doko lirilonse liri ndi 1P 20A UL489 wozungulira dera

    6. Smart mita module yokhala ndi mawonedwe a LCD aku board and control menu

    7. Efaneti/RS485 mawonekedwe, kuthandiza HTTP/SNMP/SSH2/MODBUS

    8. Kuwunika kwakutali ndikuwongolera ON / OFF pa doko lililonse

    9. Kuyika kwakutali koyang'anira ndi pa doko lapano, voteji, mphamvu, mphamvu, KWH

    10. Kuyika kwa rack-mounted, kugwiritsidwa ntchito mu data center

  • 18 Madoko P34 Smart PDU

    18 Madoko P34 Smart PDU

    Zofunikira za PDU:

    1. Kulowetsa mphamvu: 3-gawo 346-480 VAC

    2. Zomwe zilipo panopa: 3 x 150A

    3. Mphamvu yamagetsi: 3-gawo 346-480 VAC kapena gawo limodzi 200 ~ 277 VAC

    4. Kutuluka: Madoko a 18 a 6-pin PA45 Sockets okonzedwa m'magawo atatu

    5. Doko lililonse lili ndi 3P 20A Circuit Breaker (3P 16A/25A)

    6. PDU imagwirizana ndi 3-phase T21 ndi single-phase S21

    7. Kuwunika kwakutali ndikuwongolera ON / OFF pa doko lililonse

    8. Kulowetsedwa kwakutali koyang'anira, voteji, mphamvu, mphamvu, KWH

    9. Chiwonetsero cha LCD cham'mwamba chokhala ndi zowongolera menyu

    10. Efaneti/RS485 mawonekedwe, amathandiza HTTP/SNMP/SSH2/MODBUS

    11. Kukupiza mkati ndi chizindikiro cha LED

  • 3 Madoko P34 Smart PDU

    3 Madoko P34 Smart PDU

    Zofunikira za PDU:

    1. Kulowetsa mphamvu: 3-gawo 346-480 VAC

    2. Zolowetsa panopa: 3 x 30A

    3. Chingwe cholowetsa: pulagi ya L22-30P yokhala ndi chingwe cha UL ST 10AWG 5/C 6FT

    4. Mphamvu yamagetsi: 3-gawo 346-480 VAC kapena gawo limodzi 200 ~ 277 VAC

    5. Kutuluka: 3 madoko a 6-pin PA45 (P34), 3-gawo / gawo limodzi logwirizana

    6. Integrated 3P 30A chachikulu dera wosweka

    7. Kuwunika kwakutali ndikuwongolera ON / OFF pa doko lililonse

    8. Kulowetsedwa koyang'anira kutali & pa doko lamakono, magetsi, mphamvu, PF, KWH

    9. Smart Meter yokhala ndi Efaneti/RS485 mawonekedwe, thandizo http/snmp/ssh2/modbus

    10. Chiwonetsero cha LCD chapabwalo chokhala ndi zowongolera menyu ndi kuyang'anira kwanuko

  • 30 Madoko P34 Smart PDU

    30 Madoko P34 Smart PDU

    Zofunikira za PDU:

    1. Kulowetsa mphamvu: 3-gawo 346-480 VAC

    2. Zolowetsa panopa: 3 x 250A

    3. Mphamvu yamagetsi: 3-gawo 346-480 VAC kapena gawo limodzi 200 ~ 277 VAC

    4. Kutuluka: Madoko a 30 a 6-pin PA45 Sockets okonzedwa m'magawo atatu

    5. Doko lililonse lili ndi 3P 30A UL489 Circuit Breaker

    6. PDU imagwirizana ndi 3-phase T21 ndi single-phase S21

    7. Kulowetsedwa kwakutali koyang'anira, voteji, mphamvu, mphamvu, KWH

    8. Chiwonetsero cha LCD chapabwalo chokhala ndi zowongolera menyu

    9. Efaneti/RS485 mawonekedwe, kuthandiza HTTP/SNMP/SSH2/MODBUS

    10. M'kati polowera mpweya zimakupiza ndi udindo LED chizindikiro

  • 16 Madoko L7-20R Smart PDU

    16 Madoko L7-20R Smart PDU

    Zofunikira za PDU:

    1. Kulowetsa mphamvu: 3-gawo 346-480 VAC

    2. Zomwe zilipo panopa: 3 x 200A

    3. Kutulutsa mphamvu: gawo limodzi 200 ~ 277 VAC

    4. Kutuluka: 16 madoko a L7-20R Sockets

    5. Doko lililonse lili ndi 1P 25A Circuit Breaker

    6. Kulowetsedwa kwakutali koyang'anira, voteji, mphamvu, mphamvu, KWH

    7. Chiwonetsero cha LCD cham'mwamba chokhala ndi zowongolera menyu

    8. Efaneti/RS485 mawonekedwe, kuthandiza HTTP/SNMP/SSH2/MODBUS

  • 24 Madoko P34 Smart PDU

    24 Madoko P34 Smart PDU

    Zofunikira za PDU:

    1. Kulowetsa mphamvu: 3-gawo 346-480 VAC

    2. Zomwe zilipo panopa: 3 x 200A

    3. Mphamvu yamagetsi: 3-gawo 346-480 VAC kapena gawo limodzi 200 ~ 277 VAC

    4. Kutuluka: Madoko a 24 a 6-pin PA45 Sockets okonzedwa m'magawo atatu

    5. Aliyense 3P 25A Circuit Breaker amalamulira 3 sockets

    6. PDU imagwirizana ndi 3-phase T21 ndi single-phase S21

    7. Kuwunika kwakutali ndikuwongolera ON / OFF pa doko lililonse

    8. Kulowetsedwa kwakutali koyang'anira, voteji, mphamvu, mphamvu, KWH

    9. Chiwonetsero cha LCD cham'mwamba chokhala ndi zowongolera menyu

    10. Efaneti/RS485 mawonekedwe, amathandiza HTTP/SNMP/SSH2/MODBUS

    11. Kukupiza mkati ndi chizindikiro cha LED

  • 16 Madoko P34 Smart PDU

    16 Madoko P34 Smart PDU

    Zofunikira za PDU:

    1. Kulowetsa mphamvu: 3-gawo 346-480 VAC

    2. Zolowetsa panopa: 3 x 300A

    3. Mphamvu yamagetsi: 3-gawo 346-480 VAC kapena gawo limodzi 200 ~ 277 VAC

    4. Kutuluka: Madoko a 16 a 6-pin PA45 Sockets okonzedwa m'magawo atatu

     

    5. Doko lililonse lili ndi 3P 25A Circuit Breaker

    6. PDU imagwirizana ndi 3-phase T21 ndi single-phase S21

     

    7. Kuwunika kwakutali ndikuwongolera ON / OFF pa doko lililonse

    8. Kulowetsedwa kwakutali koyang'anira, voteji, mphamvu, mphamvu, KWH

    9. Chiwonetsero cha LCD cham'mwamba chokhala ndi zowongolera menyu

    10. Efaneti/RS485 mawonekedwe, amathandiza HTTP/SNMP/SSH2/MODBUS

    11. Kukupiza mkati ndi chizindikiro cha LED

123Kenako >>> Tsamba 1/3